All ORCA models feature an exclusive “Smart” flow metering system that contains no moving parts for an accurate, trouble-free service life. The ORCA controls automatically sense the Perma-Cyl float shut-off for a safe and reliable fill.
HL Models
The HL models incorporate an external pump for oxygen service or an innovative submerged pump for inert service. The submerged pump eliminates cool down time and completes a Perma-Cyl fill in 3 to 15 minutes without product loss under normal conditions.
PT & XT Models
Designed for smaller markets or as a starter system, the PT1000 delivers product efficiently from an innovative Pulse Technology process. This pump-less design uses a high-pressure pulse tank that integrates with the low-pressure main tank for a low-loss and low cost delivery solution. The XT2500 includes this feature plus a pulse pressure design to benefit larger deliveries from the main tank.
The ORCA Advantage
- Fast on-site filling of the Perma-Cyl storage system with auto shut-off and small bulk tanks
- Exclusive low maintenance submerged pump for instant starts and continuous delivery (HL)
- Pump-less pulse transfer plus pulse pressure technology reduces equipment costs and associated maintenance costs (PT)
- Single Hose Delivery system minimizes contamination and cool down losses
- Exclusive quick-disconnect maintains service integrity, reduces contamination and speeds up delivery time
- Push-button Programmable Logic Control (PLC) with manual override simplifies operator training
- Electronic pump speed control allows driver to safely optimize delivery rate (HL)
- National Institute of Standards & Technology (NIST) and California Weights & Measures approved delivery system
- Stainless steel and bronze plumbing for long service life
- Robust inner vessel support system for rugged road conditions
 Patent no's - 5,616,838 5,682,750 |
Chart Exclusive
Submerged pump for inert service. Eliminates cool down losses and reduces delivery time. |
 |
HL Series controls and plumbing |
 |
Delivery assist option for high-pressure applications |
 |
Chart Exclusive
“ Smart” flow metering system monitors flow electronically with no moving parts (standard on all models) |
|
| Model |
PT-1000 |
XT-2500 |
HL-2000 |
HL-2800 |
HL-3300 |
HL-4200 |
| Gas Services |
LIN, LAR, and LOX |
LIN, LAR, and LOX |
LIN, LAR, and LOX |
LIN, LAR, and LOX |
LIN, LAR, and LOX |
LIN |
| Dispense Method/Technology |
Pulse Transfer |
Pulse Transfer Plus Pulse Prssure |
Submerged pump, External Pump |
Submerged pump, External Pump |
Submerged pump, External Pupm |
Submerged Pump |
| Pressure Builder Type |
HP2 & ZX technologies |
HP2 & ZX technologies |
Pump force-feed |
Pump force-feed |
Pump force-feed |
Pump force-feed |
| Design Code |
ASME and CGA-341 |
ASME and CGA-341 |
ASME, MC338 and CGA-341 |
ASME, MC338 and CGA-341 |
ASME, MC338 and CGA-341 |
ASME, MC338 and CGA-341 |
| Specifications |
Overall Unit |
Main Tank |
Pulse Tank |
Overall Unit |
Main Tank |
Pulse Tank |
Overall Unit |
Overall Unit |
Overall Unit |
Overall Unit |
| Gross Capacity(gal/ltrs) |
1146 / 4337 |
1067 / 4038 |
79 / 300 |
2625 / 9927 |
2546 / 9637 |
79 / 300 |
2144 / 8100 |
2880 / 10,890 |
3399 / 12,850 |
4654 / 17,620 |
| Capacity *'** - CGA-341 (gal/ltrs) |
|
|
|
|
|
|
1907 / 7210 |
2561 / 9680 |
3023 / 11,430 |
4139 / 15,670 |
| MAWP (psig/bar) |
|
50 / 3.4 |
350 / 24.1 |
|
245 / 16.9 |
350 / 24.1 |
50 / 3.4 |
50 / 3.4 |
50 / 3.4 |
50 / 3.4 |
| Overall Length(in/cm) |
207 / 526 |
145 / 368 |
27 / 69 |
282 / 716 |
220 / 559 |
27 / 69 |
200 / 508 |
244 / 620 |
273 / 693 |
346 / 878 |
| Overall Height(in/cm) |
111 / 282 |
86 / 218 |
70 / 178 |
111 / 282 |
86 / 218 |
70 / 178 |
87 / 221 |
87 / 221 |
87 / 221 |
87 / 221 |
| Diameter/Width(in/cm) |
72 / 183 |
72 / 183 |
26 / 66 |
72 / 183 |
72 / 183 |
26 / 66 |
80 / 203 |
80 / 203 |
80 / 203 |
80 / 203 |
| Tare Weight(lbs/kg) |
6700 / 3038 |
|
|
11,570 / 5260 |
|
|
8000 / 3636 |
9000 / 4090 |
10,000 / 4545 |
11,560 / 5244 |
| Performance |
|
| Dispense Rate(gpm/lpm) |
|
10-40 / 38-151 |
|
|
10-60 / 38-227 |
10-40 / 38-151 |
4-40 / 15 - 151(1) |
4-40 / 15 - 151(1) |
4-40 / 15 - 151(1) |
4-100 / 15 - 378 |
| Max. Dispense Pressure(psig/bar) |
|
325 / 22.4 |
|
|
235 / 16.2 |
325 / 22.4 |
225 / 15.5 250 / 17.2 |
225 / 15.5 250 / 17.2 |
225 / 15.5 250 / 17.2 |
400 / 27.6 |
| Max. Recieving |
|
|
|
|
|
|
175 / 12.1 200 / 13.8 |
175 / 12.1 200 / 13.8 |
175 / 12.1 200 / 13.8 |
350 / 24.1 |
| Tank Pressure ***(psig/bar) |
|
225 / 15.5 |
|
|
135 / 9.3 |
225 / 15.5 |
|
|
|
|
| Optimum Recieving Vessel |
Small to Medium Perma-Cyl |
Large Perma-Cyls & Small Bulk |
Perma-Cyl |
Perma-Cyl & Small Bulk |
Perma-Cyl & Small Bulk |
Perma-Cyl & Small Bulk |
Perma-Cyl & Bulk |
| Requirements |
|
| Power |
12 VDC x 10 Amp |
12 VDC x 10 Amp |
12 VDC x 30 Amp & 480 VAC x 30 Amp |
12 VDC x 30 Amp & 480 VAC x 30 Amp |
12 VDC x 30 Amp & 480 VAC x 30 Amp |
12 VDC x 30 Amp & 480 VAC x 50 Amp |
| Truck**** |
Single axle sized for service, below FET |
Double axle sized for service |
Single or Double axle sized for service |
Double axle sized for service |
Double axle sized for service |
|
| Air ride required |
GVW 23,500 lbs to 31,000 lbs |
GVW 32,000 lbs to 46,000 lbs |
GVW 32,000 lbs to 46,000 lbs |
GVW 32,000 lbs to 46,000 lbs |
GVW 32,000 lbs to 46,000 lbs |
|
| Trailer**** |
Available - consult factory |
Available - consult factory |
Available - consult factory |
Available - consult factory |
Available - consult factory |
Trailer Only |
* With road relief valve at 25.3 psig
*** For optimum single hose, no-loss fill
|
** Maximum fill levels depend on vehicle specifications
**** Customer supplied per Chart's requirements
|
MAWP, Maximum Allowable Work Pressure / NIST, National Institute of Standards and Technology /
FET, Federal Exise Tax / DP, Differential Pressure
Specifications subject to change without notice
(1)Models Available with 80 100gpm @ 400 psi submerged pump for nitrogen and Argon service
|
|